Skip to content
The Calculatorz
Molecular biology

DNA & RNA Concentration Calculator (A260)

Convert A260 absorbance into DNA or RNA concentration, total yield and A260/A280 purity.

Results are calculation aids for study and laboratory planning. Follow your protocol, kit instructions and supervisor's guidance, and verify critical values independently.

Absorbance readings

Measurement

How to use this calculator

Enter the A260 reading for a 1 cm path length, the type of nucleic acid and how much the sample was diluted before measuring (1 if undiluted). Add the A280 reading to check protein contamination and the sample volume to calculate total yield. Readings are most reliable between about 0.1 and 1.0 absorbance units.

Formula

Concentration (µg/mL, equal to ng/µL) = A260 × conversion factor × dilution factor, with factors of 50 for dsDNA, 40 for RNA and 33 for ssDNA. Total yield (µg) = concentration (ng/µL) × volume (µL) ÷ 1,000. Purity ratio = A260 ÷ A280.

Calculator credits

Calculator developmentJulia Edwards

Editorial supervision

Expert reviewJanBioinformatics Graduate, Genomic Data Analyst

Published byThe Calculatorz

Last updated

Read how we research, test, review and correct our calculators in our editorial policy.

Frequently asked questions

What A260/A280 ratio means pure DNA?

A ratio of about 1.8 is generally accepted as pure DNA and about 2.0 as pure RNA. Lower ratios can indicate protein or phenol contamination.

What is the A260/A230 ratio?

It indicates contamination from salts, carbohydrates or guanidine. Values of roughly 2.0–2.2 are typical for clean nucleic acid; this calculator focuses on A260 and A280.

Why are the conversion factors different?

Single-stranded nucleic acids absorb more UV light per microgram than double-stranded DNA, so less mass gives the same absorbance.

What if my microvolume spectrophotometer reports ng/µL directly?

It applies the same factors and path-length correction automatically. Use this calculator for cuvette readings or to check results.

Does A260 tell me the DNA is intact?

No. It measures total absorbance, including degraded fragments and free nucleotides. Use gel or capillary electrophoresis to check integrity.

What concentration range is reliable?

Very low readings are noisy and very high readings can be non-linear. Dilute or concentrate the sample to keep A260 roughly between 0.1 and 1.0.

References & methodology sources

These sources support the calculator’s formula, definitions, thresholds, units or result interpretation.

  1. QIAGEN. (n.d.). Spectrophotometric measurement of DNA concentration. In Bench guide: Analysing DNA. View source
  2. Sigma-Aldrich. (n.d.). DNA and RNA quantification [Technical article]. View source
  3. Bustin, S. A., et al. (2009). The MIQE guidelines: Minimum information for publication of quantitative real-time PCR experiments. Clinical Chemistry, 55(4), 611–622. View source
  4. Flowers, P., Theopold, K., Langley, R., & Robinson, W. R. (2019). Chemistry 2e. OpenStax. View source
  5. Thompson, A., & Taylor, B. N. (2008). Guide for the use of the International System of Units (SI) (NIST Special Publication 811). National Institute of Standards and Technology. View source