Skip to content
The Calculatorz
Molecular biology

Ligation Calculator (Insert : Vector Ratio)

Calculate how much insert DNA to add to a ligation for a chosen insert-to-vector molar ratio.

Results are calculation aids for study and laboratory planning. Follow your protocol, kit instructions and supervisor's guidance, and verify critical values independently.

Vector, insert and ratio

Ligation

How to use this calculator

Enter the amount of linearised vector in the reaction, the vector and insert lengths in base pairs, and the molar ratio. The calculator gives the mass of insert to add, and the picomoles of each fragment, so the number of insert molecules matches the chosen ratio.

Formula

Insert mass (ng) = vector mass (ng) × (insert length ÷ vector length) × molar ratio. Picomoles of a dsDNA fragment = mass (ng) × 1,000 ÷ (length in bp × 660).

Calculator credits

Calculator developmentJulia Edwards

Editorial supervision

Expert reviewJanBioinformatics Graduate, Genomic Data Analyst

Published byThe Calculatorz

Last updated

Read how we research, test, review and correct our calculators in our editorial policy.

Frequently asked questions

What insert-to-vector ratio should I use?

A 3 : 1 insert-to-vector molar ratio is a common starting point. Very short inserts may benefit from higher ratios such as 5 : 1 or 10 : 1, and similar-sized fragments from 1 : 1.

Why use molar ratios instead of mass?

Ligation joins DNA ends, so the number of molecules matters. A short insert has many more molecules per nanogram than a long vector.

How much vector should I use?

Many protocols use 20–100 ng of vector in a 20 µL reaction. Follow your ligase supplier's recommendations for total DNA concentration.

Should I dephosphorylate the vector?

Dephosphorylating a vector cut with a single enzyme reduces self-ligation and background colonies. It is not needed for directional cloning with two incompatible ends.

Does this work for Gibson or other assembly methods?

The molar-ratio principle is similar, but assembly kits often recommend specific ratios and total amounts. Follow the kit instructions.

Why does my ligation fail even with the right ratio?

Common causes include inactive ligase or ATP, damaged ends, residual salts or enzymes from purification, and incompatible ends.

References & methodology sources

These sources support the calculator’s formula, definitions, thresholds, units or result interpretation.

  1. New England Biolabs. (n.d.). How to calculate the molarity of ends? [FAQ]. View source
  2. New England Biolabs. (n.d.). How do I calculate how much DNA to add to a ligation reaction? [Video]. View source
  3. QIAGEN. (n.d.). Ligation calculator. View source
  4. Parker, N., Schneegurt, M., Thi Tu, A.-H., Lister, P., & Forster, B. M. (2016). Microbiology. OpenStax. View source