Beer–Lambert Law Calculator (Absorbance and Concentration)
Solve the Beer–Lambert law A = εlc for concentration, absorbance, molar absorptivity or path length, with transmittance and the reliable range.
Calculations use standard textbook models and ideal behaviour. Real solutions, gases and reactions can differ; follow your laboratory's safety data sheets and procedures.
What is the Beer–Lambert law?
The Beer–Lambert law states that the absorbance of light by a solution equals the molar absorptivity of the substance times the path length times its concentration: A = εlc. It is the basis of spectrophotometry, used to measure concentrations of everything from DNA and proteins to pollutants and dyes.
How to use this calculator
Choose the quantity to find and enter the other three; the value in the box you are solving for is ignored. Most cuvettes have a 1 cm path length. Molar absorptivity depends on the substance and wavelength.
Formula
A = ε × l × c, where A is absorbance (no units), ε the molar absorptivity in M⁻¹ cm⁻¹, l the path length in cm and c the concentration in mol/L. Transmittance %T = 10^(−A) × 100.
Terms in the formula
- A
- Absorbance (no units).
- ε
- Molar absorptivity (M⁻¹ cm⁻¹).
- l
- Path length (cm).
- c
- Concentration (M).
- %T
- Percent transmittance.
Understanding your result
Because absorbance is proportional to concentration, a measured absorbance can be converted directly into concentration once ε and the path length are known. Results are most reliable for absorbances between about 0.1 and 1.0; dilute samples that read higher, and check linearity with a calibration curve.
Calculator credits
Calculator developmentJulia Edwards
Editorial supervisionSamad Aslam Khan
Expert reviewAslamResearcher, Chemical Engineer
Published byThe Calculatorz
Last updated
Read how we research, test, review and correct our calculators in our editorial policy.
Frequently asked questions
What is the Beer–Lambert law?
It states that absorbance is proportional to both the concentration of the absorbing substance and the distance light travels through it.
What is a good absorbance range?
About 0.1 to 1.0 for most spectrophotometers. Below that, noise dominates; above it, little light reaches the detector and the law can stop being linear.
What is the difference between absorbance and transmittance?
Transmittance is the fraction of light that passes through; absorbance is −log₁₀ of transmittance. An absorbance of 1 means 10% of the light gets through.
Why does the Beer–Lambert law fail at high concentrations?
Molecules start to interact, the refractive index changes and stray light becomes significant, so absorbance no longer rises in proportion.
Where do I find molar absorptivity?
In the literature or from a calibration curve: measure standards of known concentration and use the slope of absorbance against concentration.
Can I use mass concentration instead of molarity?
Yes, with a mass absorptivity in L g⁻¹ cm⁻¹. The A280 of a protein at 1 mg/mL, from the protein molecular weight calculator, is one example.
References & methodology sources
These sources support the calculator’s formula, definitions, thresholds, units or result interpretation.
- Swinehart, D. F. (1962). The Beer–Lambert law. Journal of Chemical Education, 39(7), 333. View source
- Mayerhöfer, T. G., Pahlow, S., & Popp, J. (2020). The Bouguer–Beer–Lambert law: Shining light on the obscure. ChemPhysChem, 21(18), 2029–2046. View source
- Flowers, P., Theopold, K., Langley, R., & Robinson, W. R. (2019). Chemistry 2e. OpenStax. View source